Product Details:
|
Ac Voltage: | 220-240V | Output Current: | 1051-1500mA |
---|---|---|---|
Output Voltage Range: | 30-60V | Max. No Load Voltage: | 70V |
Input Current: | 330mA | Frequency: | 50/60Hz |
Power Factor: | ≥0.9 | Efficiency: | ≥89% |
Lifetime: | 30000H | Dimension: | 150x41.6x29mm |
Certification: | CE/TUV-GS | ||
High Light: | TUV constant voltage led driver,2500mA constant voltage led driver,led driver 12v 60w |
60W-12V constant voltage LED driver with TUV CE SAA CCC Approval
1. Safety & EMC standard: EN61347-1 EN61347-2-13;EN55015, EN61000-3-2/3 , EN61547. |
|
2. Electrical Performance : The Supply shall operate over the voltage ranges as follows
|
|
Rated input voltage | 100-240VAC |
Operating range | 90-264VAC |
Rated input frequency | 50/60Hz±3Hz |
Power consumption (no loading) | ≤0.5W |
Primary current protection | An adequate internal fuse on the AC input line is provide. |
OUTPUT REQUIREMENTS: | |
Max dc output voltage | 24V |
Rating load current | 2500mA |
Rating output power | 60W |
Short-circuit protection | The driver shall not damage and with auto recovery function by short the DC output to Ground |
Over-voltage protection | The output voltage shall be clamped by internal protection IC |
3. HI-POT Test: Between live parts and the enclosure: – for basic insulation – for reinforced insulation Between input circuits and output circuits Between metal parts of class II controlgear which are separated from live parts by basic insulation only and the enclosure Between metal foil in contact with the inner and outer surface of enclosures of insulating material Shall Withstand Without Breakdown: 3-1. AC 3750 V 60 sec between input (AC short)to output(DC short)(Cut-off current:10mA); 3-2. AC 3750 V 60 sec between input(AC short) to crust(Cut-off current:10mA); 3-3. AC 1000 V 60sec between output(DC short) to crust(Cut-off current:10mA); 3-4. Leakage Current: The leakage current shall be less than 3mA for Class II when product is operated maximum input voltage and maximum load.
4. Isolation Resistance: 4-1. Input to output ≥5MΩ , DC 500V; 4-2. Input to crust≥5MΩ , DC 500V;
5.Environment: working temperature of 0°C~45°C , 10%~90%RH (without dew point); Storage temperature: -20°C~85°C , 10%~90%RH (without dew point);
6. Structure: Cooling in natural way..
7. Aging Test: The product operate continuously for four hours at a rated load. |
8. Humidity Test: After exposed to 45±2℃ , 90-95℅RH for 48 hours, and then put it into normal ambient condition treated for 30 minutes. The test result must be satisfied with item 3. & item 4.
9. Temperature Test:(Ta=45℃ MAX) A component part temperature shall not exceed the manufacturer’s maximum of the thermal rating and the maximum temperature rise not exceed 80℃ . 10. Instruction: 10-1. Turn off the power connection before installation. 10-2. Indoor use only. 10-3. Load of the secondary shall not exceed the rated power. 10-4. Installation shall be done by qualified technician. 10-5. Make sure all the cables connected correctly before turn on the power. 10-6.Maximum ambient temperature 45℃
11. Externality figure and name plate:
|
12. Certificate: CE/TUV